Electrocardiograph / ECG300G

Electrocardiograph, 3 Channel with monitor 

CONTEC ECG300G

ECG300G is an Electrocardiograph which can collect 12-lead ECG signal and print waveform by the thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting any rhythm lead, case database management.

Function :
  1.  Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
  2.  Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
  3.  Multiply printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
  4.  With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
  5.  Built-in memory stores up to 1000 cases, convenient for case review and statistic.
  6.  Multi-language(Chinese, English, Spanish, Turkish, Polish, Italian, French, German, Portuguese, Kazakstan, Russian, Ukrainian, Serbian and Slovenian) interface and report.
Technical Specification :   
| ECG instrument Input :  
  • Safety Type : Class I, type CF applied part, which has defi brillation-proof applied part  
  •  Lead : Standard 12 leads  
  • Input way : Floating and defi brillation protection  
  •  Patient leak current : <10μA  
  •  Sampling rate : 1,000 Hz  
  •  A/D conversion : 12bit  
  •  Frequency response : 0.05Hz~150Hz (-3dB, + 0.4dB)  
  •  Time constant : ≥ 3.2s  
  •  CMRR : >60dB, >100dB(Add fi lter)  
  •  Enduring polarization voltage : ±500mV  
  •  Noise level : <15μVp-p   
| Waveform output :
  • Recording way : Thermal printing system (32spots/mm)   
  •  Recording paper : 80mm(W)×20m(L)  
  •  Sensitivity : 2.5, 5, 10, 20, 40 mm/mV  
  •  Paper speed :
  1. Auto-record: 25mm/s, 50mm/s
  2. Rhythm record: 25 mm/s, 50 mm/s
  3. Manual-record: 5, 6.25, 10, 12.5, 25, 50  
| Power supply :
  •  AC : 110-220V, 50/60 Hz  
  •  DC - Lithium battery : 7.4V, 2000 mAh 7.4V, 3500 mAh