google pixel 6 google pixel 6

Electrocardiograph / ECG1212G

Electrocardiograph Touch Screen

ECG1212G
The device is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in auto / manual mode; measuring, analyzing and diagnosing ECG waveform parameters automatically; prompting for “Lead off” and “Lack of paper”; optional interface language (Chinese / English, etc.); built-in lithium battery, AC / DC; selecting rhythm lead freely to observe abnormal heart rhythm; case database management.

Functions :
  1.  Adopt 10.1'' high-resolution color LCD, operate by full-touch screen and function bu ttons, convenient to use.
  2.  Sync collection for 12-lead ECG, support 12-lead and Cabrera-lead waveform display. Get high-quality ECG waveform via power frequency filter (50 / 60 Hz), baseline filter and EMG filter (25 / 35 Hz) of ECG signal.
  3.  Display 3 / 6 / 12 - lead ECG waveform, HR value, print mode, sensitivity, paper speed, filter state, clock, battery power, background grid, measured parameter and interpretation, etc. on one screen, and with prompt functions for lead - off, overload and system working state.
  4.  Power supply: AC / DC (which can adapt AC 50 / 60Hz), with built-in rechargeable lithium battery, charging circuit, perfect over-current and over-voltage protection circuit.
  5.  In optimal DC state, up to 10-hour standby time, continuous print for more than 3-hour, which meets the requirements of visiting a patient at home and body examination.
Specification :   
| Input mode : floating and defibrillation protection
| Lead : standard 12-lead
| Patient leak current : < 10 µA
| Input impedance : ≥ 2.5 MΩ
| Time constant : ≥ 3.2 s
| CMRR : > 105 dB
| Recording mode : thermal printing system
| Paper size : 210 mm (W) × 20 m (L), high-speed thermal paper
| Paper speed : 12.5 mm/s, 25 mm/s, 50 mm/s, error: ± 5 %
| Gain (sensitivity) : 5, 10, 20 mm / mV, accuracy: ± 2 %
| Standard sensitivity : 10 mm/mV ± 0.2 mm/mV
| Record mode : auto, rhythm and manual record
| Measurement parameters : HR, P - R interval, P Duration, QRS Duration, T Duration, Q - T interval, Q - Tc, P Axis, QRS Axis, T Axis, R (V5) amplitude, S (V1) amplitude, R (V5) + S (V1) amplitude
| Safety class : class I, defibrillation-proof type CF applied part
| Polarizing voltage : ± 610 mV
| Noise level : ≤ 12 µVp-p
| Sampling frequency for ECG signal input :  32 kHz
| Sampling frequency for waveform data processing : 1 kHz
| Pacemaker detection channel : II
| Time deviation in each channel : <100 µs
| Power supply : 
  • AC: 100V ~ 240V (50 / 60 Hz)
  • DC: 14.8 V / 5200 mAh rechargeable lithium battery
| Working mode : Continuous operation